5-3
5.3 Moving to other groups
l There are 4 different parameter groups in SV- iG5A series as shown below.
Drive group Basic parameters necessary for the inverter to run. Parameters
such as Target frequency, Accel/Decel time settable.
Function group 1 Basic function parameters to adjust output frequency and
voltage.
Function group 2 Advanced function parameters to set parameters for such as
PID Operation and second motor operation.
I/O (Input/Output)
group
Parameters necessary to make up a sequence using Multifunction input/output terminal.
l Moving to other parameter groups is only available in the first code of each group as the
figure shown below.
Moving to other groups using the Right (u)
key
Moving to other groups using the Left (t) key
Function
group 1
Function
group 2
I/O group
Drive group
*
Function
group 1
Function
group 2
I/O group
Drive group
*
* Target frequency can be set at 0.0 (the 1st code of drive group). Even though the preset value is 0.0, it is
user-settable. The changed frequency will be displayed after it is changed.
I/O group
FU group 2
FU group 1
Drive group
5-4
l How to move to other groups at the 1st code of each group
1
-. The 1st code in Drive group “0.00” will be displayed when AC input
power is applied.
-. Press the right arrow (u) key once to go to Function group 1.
2
-. The 1st code in Function group 1 “F 0” will be displayed.
-. Press the right arrow (u) key once to go to Function group 2.
3
-. The 1st code in Function group 2 “H 0” will be displayed.
-. Press the right arrow (u) key once to go to I/O group.
4
-. The 1st code in I/O group “I 0” will be displayed.
-. Press the right arrow (u) key once again to return to Drive group.
5 -. Return to the 1st code in Drive group “0.00”.
ß If the left arrow key (t) is used, the above will be executed in the reverse order.
l How to move to other groups from any codes other than the 1st code
To move from the F 15 to function group 2
1
-. In F 15, press the Left (t) or Right arrow (u) key. Pressing the key goes to
the first code of the group.
2
-. The 1st code in function group 1 “F 0” is displayed.
-. Press the right arrow (u) key.
3 -. The 1st code in function group 2 “H 0” will be displayed.
Pressing left or
right arrow key in
any code will
return to first
code of each
group.
Drive group FU group 1 FU group 2