5-3

5.3 Moving to other groups

l There are 4 different parameter groups in SV- iG5A series as shown below.

Drive group Basic parameters necessary for the inverter to run. Parameters

such as Target frequency, Accel/Decel time settable.

Function group 1 Basic function parameters to adjust output frequency and

voltage.

Function group 2 Advanced function parameters to set parameters for such as

PID Operation and second motor operation.

I/O (Input/Output)

group

Parameters necessary to make up a sequence using Multi￾function input/output terminal.

l Moving to other parameter groups is only available in the first code of each group as the

figure shown below.

Moving to other groups using the Right (u)

key

Moving to other groups using the Left (t) key

Function

group 1

Function

group 2

I/O group

Drive group

*

Function

group 1

Function

group 2

I/O group

Drive group

*

* Target frequency can be set at 0.0 (the 1st code of drive group). Even though the preset value is 0.0, it is

user-settable. The changed frequency will be displayed after it is changed.

I/O group

FU group 2

FU group 1

Drive group

5-4

l How to move to other groups at the 1st code of each group

1

-. The 1st code in Drive group “0.00” will be displayed when AC input

power is applied.

-. Press the right arrow (u) key once to go to Function group 1.

2

-. The 1st code in Function group 1 “F 0” will be displayed.

-. Press the right arrow (u) key once to go to Function group 2.

3

-. The 1st code in Function group 2 “H 0” will be displayed.

-. Press the right arrow (u) key once to go to I/O group.

4

-. The 1st code in I/O group “I 0” will be displayed.

-. Press the right arrow (u) key once again to return to Drive group.

5 -. Return to the 1st code in Drive group “0.00”.

ß If the left arrow key (t) is used, the above will be executed in the reverse order.

l How to move to other groups from any codes other than the 1st code

To move from the F 15 to function group 2

1

-. In F 15, press the Left (t) or Right arrow (u) key. Pressing the key goes to

the first code of the group.

2

-. The 1st code in function group 1 “F 0” is displayed.

-. Press the right arrow (u) key.

3 -. The 1st code in function group 2 “H 0” will be displayed.

Pressing left or

right arrow key in

any code will

return to first

code of each

group.

Drive group FU group 1 FU group 2

Tải ngay đi em, còn do dự, trời tối mất!