Thư viện tri thức trực tuyến
Kho tài liệu với 50,000+ tài liệu học thuật
© 2023 Siêu thị PDF - Kho tài liệu học thuật hàng đầu Việt Nam

SƠ ĐỒ ĐIỆN THÂN XE SHACMAN F3000
Nội dung xem thử
Mô tả chi tiết
B
B
G100
G101
B
B+
91 90
31
30010
G
X100 X102 X101
L L
G102
L
92
X244
31
M
L L
X238/H
A
L
1 2
46
X157 12
F12
15A
83/4 87/2
M100
X316/42
9
F9
15A
86/2
36
X139 2
F2
20A
81/3
36
X140 1
F1
15A
81/5
A
4
82/5
3
F3
20A
86/5 81/7
Q101
2
30 86 85 87 1 2
V100 K171
43
89/7
5
3
7
6
8
30010
1
86/8
P
15
0R
R
19
0
R
1
2
3
50
30
94
53
A100
F12
30006
30016
A02
30014
E08
30012
F06
30015
A08
30013
E02
15002 15003
F05
A03 B07 B08 C42 C43 C44 E01
CBCU
L L L L L L L
L L
L
1/3 1/3 1/3 1/3 1/3 1/3 1/3
30000 30006 30010
83/7
1/11
1/21
30006 30006
CBCU
X238/A X238/F
X238/C
M
G1 G6 G4 G2 G5 G3
2/35
2/39
2/49
3/21
F4
20A
F09
L
1/3
1/23
1/24
1/25
1/26
1/27
1/28
1/29
1/30
30010-90
30010-91
31000
15001
30010
30010
30010
86/7
6/4
5 5
50
1 5
30 D+
10 1 5 2 0 25
B
S149
30 3 5 40 45 5 0
W
Battery cabinet
A100 central elecrical panel
CBCU control system of the main element of the housing CAN
F1 Fuse CBCU (30-G3)
F2 Fuse CBCU (30-G5)
F3 Fuse CBCU (30-G4)
F4 Fuse CBCU (30-G6)
F9 Fuse CBCU (30-G2)
X238 cabin driver hole №35 chassis connector
X244Т panel grounding point
S149 General power switch V100
Anti-interfenrence load diode
X100 flywheel motor ground point
X101 front box ground point
X102 Attachment point of the right stringer X139
Connecting plate
X157 Connecting plate
UNINTERRUPTED POWER SUPPY SYSTEM
Main power
Terminal
source
current
Diagnostic interface
PPower Circuit
wiring diagram model F3000 (in terms of charging the bus system CAN)
F12 Uninterrup tible power supply fuse(CBCU-G1)
G100 battery group 1
G101 Battery group 2
G102 generator
K171 Starter relay
M100 Starter motor
Q101 Shutdown key
Explanations:
1) There are 6 connectors A-F on the CBCU, during installation and installation work, it is necessary to
follow the installation order from A to F, when dismantling, disassembling, it is necessary to follow the
reverse order, that is, from F to A. When carrying out welding work, it is necessary to remove the CBCU
connectors. The designation AO2 in the diagram means hole No. 2 of connector A
.2) CBCU power supplies have serial numbers G1 to G6, which are provided for ease of service. During the repair work, it will be quite easy to find a malfunction. The message about the malfunction of the current source G6 means that it is necessary to find the source of line A02.
Alarm
Disconnect
Terminal 30 (Main Switch) Power key
of Power supply