Mô tả chi tiết
Transformers
PSIM User Manual 2-19
Images:
In the images, p refers to primary, s refers to secondary, and t refers to tertiary.
The winding with the larger dot is the primary winding (or the first primary winding for
the 2-primary-2-secondary-winding transformer (TF_1F_4W)). For the multiple winding
transformers, the sequence of the windings is from the top to the bottom.
For the transformers with 2 or 3 windings, the attributes are as follows.
Attributes:
All the resistances and inductances are referred to the primary side.
For the transformers with more than 1 primary winding or more than 3 secondary windings, the attributes are as follows.
Parameters Description
Rp (primary);
Rs (secondary);
Rt (tertiary)
Resistance of the primary/secondary/tertiary winding, in
Ohm
Lp (pri. leakage);
Ls (sec. leakage);
Lt (ter. leakage)
Leakage inductance of the primary/secondary/tertiary
winding, in H (seen from the primary)
Lm (magnetizing) Magnetizing inductance, in H
Np (primary);
Ns (secondary);
Nt (tertiary)
No. of turns of the primary/secondary/tertiary winding
TF_1F_4W
p_1
p_2
s_1
s_2
TF_1F_8W
p_1
p_2
s_1
s_2
s_6
TF_1F TF_1F_3W TF_1F_5W TF_1F_7W
p s
t
p
p
p
s s_1
s_4
s_1
s_6
s_2
p s
TF_1F_1
TF_1F_5W _1
p_1
p_2
s_1
s_3