Mô tả chi tiết

KL-620

Microcomputer Sensing Control System

Training Course

Main Unit

Unit 0 : KL-62001

General

Sensors (I)

Unit 1 : KL-64001

General

Sensors (II)

Unit 2 : KL-64002

Pressure

Strain Gauge

Unit 7 : KL-64007

F/V Converter

Unit 11 : KL-64011

CDS

Photovoltaic

Unit 9 : KL-64009

V/F Converter

Unit 10 : KL-64010

Temp II (PT100)

Unit 12 : KL-64012

Fiber Optic

Unit 14 : KL-64014

Hall Current

Proximity

Unit 8 : KL-64008

LVDT

Unit 15 : KL-64015

Gas/Smoke

Ethanol

Unit 4 : KL-64004

Rotation Angle

Unit 16 : KL-64016

Level (Water)

Unit 13 : KL-64013

Infrared

Ultrasonic

Unit 6 : KL-64006

General

Sensors (III)

Unit 3 : KL-64003

Temp I (AD590)

Humidity

Unit 5 : KL-64005

Main Unit

Unit 0 : KL-62001

In this Unit, the operation of each block on Main Unit will be introduced.

After study complete, users are able to use KL-62001 as measurement

and assist tool for KL-620 experiments.

Menu

1. System Test

2. DCV Measurement (Manual)

3. DCV Measurement (Chip)

4. DCV Measurement (PC)

5. D/A Converter Test

6. Alarm Amplifier Test

7. Comparator Test

8. Differential Amplifier Test

9. Instrumentation Amplifier

10. Other MCU Function Test

System Test

Single Chip

Out Control 2

Out Control 3

Status Display

Thumbwheel Switch

EPROM

Blocks to be demonstrated:

Objective:

To understand how to self test Single Chip and EPROM.

Back

Procedure:

1. Turn off the power. Connect the wires as shown in next slide.

2. Turn on the power.  If the speaker beep 4 times and the Status

Display shows “1”, it means that the Single Chip and EPROM work

functionally.

3. Remove Control2 from Ground.  The Status Display will display the

value shown on Thumbwheel Switch.

4. Adjust the Thumbwheel Switch below 4095.  The Status Display will

show the current value of the Thumbwheel Switch.

5. Adjust the Thumbwheel Switch over 4095  The speaker will alarm and

the Status Display shows “0000”.

Control3  GND

Control2  GND

DCV Measurement (Manual)

Objective:

To understand how to use Potentiometer.

To use DC Voltage Meter to measure DC Voltage manually.

DC Power

+12V, -12V

Select / Manual

Status Display

MODE Button

Range Button

Blocks to be demonstrated:

Potentiometer

Back

Procedure:

1. Turn off the power.

2. Connect the wires as shown in next slide.

3. Turn on the power.

4. Press Range button twice.  Select the measuring range of DCV ( -20V

~ +20V)

5. Rotate the Potentiometer.  The output voltage at VR2 will display at

Status Display section (-12V ~ +12V) .

Discussion:

When connects MANUAL to the GND,

Status Display Section acts as DC

Voltage Meter.

+Input  VR2

-12V  VR1

Manual  GND

+12V  VR3

Connect to GND

DCV Measurement (Chip)

Objective:

Use A/D Converter, Single Chip and Status Display to measure DC voltage

DC Power

+5V, GND

Select / Chip

Status Display

MODE Button

Range Button

Blocks to be demonstrated:

Potentiometer

A/D Converter

Back

Procedure:

1. Turn off the power.

2. Connect the wires as shown in next slide.

3. Turn on the power.

4. Press Range button twice.  Select the measuring range of DCV ( -20V

~ +20V)

5. Rotate the Potentiometer.  The output voltage at VR2 will display at

Status Display section (0V ~ +5V) .

Discussion:

1. When connecting CHIP to the GND,

the analog signal received from A/D

Converter will send to single chip for

decoding and output to 7 segment

display.

2. When sending the analog signal to

the PC, the signal should be

converted to digital format. As the

result, this technique will be used

when connecting the main unit to the

PC. Check next exercise.

Warning!!

The max voltage input to ADC is 5V.

A/D IN  VR2

+5V  VR1

GND  VR1

Chip  GND

DCV Measurement (PC)

Objective:

Use computer interface to acquire and record DC voltage

DC Power

+5V, GND

Select / Chip

RS-232C

Blocks to be demonstrated:

Potentiometer

A/D Converter

Back

Procedure:

1. Turn off the power and connect the wires as shown in next slide.

2. Connects RS-232C port to PC COM port by using K&H RS-232 Cable.

3. Turn on the power and launch the KL-620 software.

4. Press the [Acquire] button.  Start to record the DC voltage.

5. Rotate the Potentiometer.  The output voltage at VR2 will display at

software panel.

Discussion:

When connecting CHIP to the GND and

CTRL pin to GND, the analog signal

received from A/D Converter will send

to PC through RS-232 interface.

Warning!!

The max voltage swing input to ADC is -5V ~ +5V.

A/D IN  VR2

+5V  VR3

GND  VR1

Chip  GND

CTRL  GND

Connect to PC COM1