KL-620
Microcomputer Sensing Control System
Training Course
Main Unit
Unit 0 : KL-62001
General
Sensors (I)
Unit 1 : KL-64001
General
Sensors (II)
Unit 2 : KL-64002
Pressure
Strain Gauge
Unit 7 : KL-64007
F/V Converter
Unit 11 : KL-64011
CDS
Photovoltaic
Unit 9 : KL-64009
V/F Converter
Unit 10 : KL-64010
Temp II (PT100)
Unit 12 : KL-64012
Fiber Optic
Unit 14 : KL-64014
Hall Current
Proximity
Unit 8 : KL-64008
LVDT
Unit 15 : KL-64015
Gas/Smoke
Ethanol
Unit 4 : KL-64004
Rotation Angle
Unit 16 : KL-64016
Level (Water)
Unit 13 : KL-64013
Infrared
Ultrasonic
Unit 6 : KL-64006
General
Sensors (III)
Unit 3 : KL-64003
Temp I (AD590)
Humidity
Unit 5 : KL-64005
Main Unit
Unit 0 : KL-62001
In this Unit, the operation of each block on Main Unit will be introduced.
After study complete, users are able to use KL-62001 as measurement
and assist tool for KL-620 experiments.
Menu
1. System Test
2. DCV Measurement (Manual)
3. DCV Measurement (Chip)
4. DCV Measurement (PC)
5. D/A Converter Test
6. Alarm Amplifier Test
7. Comparator Test
8. Differential Amplifier Test
9. Instrumentation Amplifier
10. Other MCU Function Test
System Test
Single Chip
Out Control 2
Out Control 3
Status Display
Thumbwheel Switch
EPROM
Blocks to be demonstrated:
Objective:
To understand how to self test Single Chip and EPROM.
Back
Procedure:
1. Turn off the power. Connect the wires as shown in next slide.
2. Turn on the power. If the speaker beep 4 times and the Status
Display shows “1”, it means that the Single Chip and EPROM work
functionally.
3. Remove Control2 from Ground. The Status Display will display the
value shown on Thumbwheel Switch.
4. Adjust the Thumbwheel Switch below 4095. The Status Display will
show the current value of the Thumbwheel Switch.
5. Adjust the Thumbwheel Switch over 4095 The speaker will alarm and
the Status Display shows “0000”.
Control3 GND
Control2 GND
DCV Measurement (Manual)
Objective:
To understand how to use Potentiometer.
To use DC Voltage Meter to measure DC Voltage manually.
DC Power
+12V, -12V
Select / Manual
Status Display
MODE Button
Range Button
Blocks to be demonstrated:
Potentiometer
Back
Procedure:
1. Turn off the power.
2. Connect the wires as shown in next slide.
3. Turn on the power.
4. Press Range button twice. Select the measuring range of DCV ( -20V
~ +20V)
5. Rotate the Potentiometer. The output voltage at VR2 will display at
Status Display section (-12V ~ +12V) .
Discussion:
When connects MANUAL to the GND,
Status Display Section acts as DC
Voltage Meter.
+Input VR2
-12V VR1
Manual GND
+12V VR3
Connect to GND
DCV Measurement (Chip)
Objective:
Use A/D Converter, Single Chip and Status Display to measure DC voltage
DC Power
+5V, GND
Select / Chip
Status Display
MODE Button
Range Button
Blocks to be demonstrated:
Potentiometer
A/D Converter
Back
Procedure:
1. Turn off the power.
2. Connect the wires as shown in next slide.
3. Turn on the power.
4. Press Range button twice. Select the measuring range of DCV ( -20V
~ +20V)
5. Rotate the Potentiometer. The output voltage at VR2 will display at
Status Display section (0V ~ +5V) .
Discussion:
1. When connecting CHIP to the GND,
the analog signal received from A/D
Converter will send to single chip for
decoding and output to 7 segment
display.
2. When sending the analog signal to
the PC, the signal should be
converted to digital format. As the
result, this technique will be used
when connecting the main unit to the
PC. Check next exercise.
Warning!!
The max voltage input to ADC is 5V.
A/D IN VR2
+5V VR1
GND VR1
Chip GND
DCV Measurement (PC)
Objective:
Use computer interface to acquire and record DC voltage
DC Power
+5V, GND
Select / Chip
RS-232C
Blocks to be demonstrated:
Potentiometer
A/D Converter
Back
Procedure:
1. Turn off the power and connect the wires as shown in next slide.
2. Connects RS-232C port to PC COM port by using K&H RS-232 Cable.
3. Turn on the power and launch the KL-620 software.
4. Press the [Acquire] button. Start to record the DC voltage.
5. Rotate the Potentiometer. The output voltage at VR2 will display at
software panel.
Discussion:
When connecting CHIP to the GND and
CTRL pin to GND, the analog signal
received from A/D Converter will send
to PC through RS-232 interface.
Warning!!
The max voltage swing input to ADC is -5V ~ +5V.
A/D IN VR2
+5V VR3
GND VR1
Chip GND
CTRL GND
Connect to PC COM1