Thư viện tri thức trực tuyến
Kho tài liệu với 50,000+ tài liệu học thuật
© 2023 Siêu thị PDF - Kho tài liệu học thuật hàng đầu Việt Nam

Guide for Sound Insulation in Wood Frame Construction Part 10 docx
Nội dung xem thử
Mô tả chi tiết
Page 99 of 103
IRC RR-219: Guide for Sound Insulation in Wood Frame Construction March 2006
Drawing SFFIGB33.pdf
Partition Wall
Single stud, details specific to the wall/floor junction case.
Corridor Wall
CW1: Single 2x6 (38x140 mm) wood stud wall with studs spaced 16” (406 mm) o.c., with double head plate.
CW2: 6” (140 mm) Unfaced Thermal/Acoustic Batt Insulation filling the wall cavity.
CW3: Two layers of 5/8” (15.9 mm) SHEETROCK® BRAND FIRECODE C CORE gypsum panels attached directly to the
studs. The base layer attached vertically using 1-5/8” (42 mm) drywall screws spaced 24” (610 mm) o.c. The face
layer attached vertically and fastened with 2” (52 mm) or longer screws placed 16” (406 mm) o.c. Joints staggered
by at least 16” (406 mm).
CW4: One layer of 5/8” (15.9 mm) SHEETROCK® BRAND FIRECODE C CORE gypsum panels attached via resilient
channels. The panels attached to the channels using 1-5/8” (42 mm) drywall screws placed 12” (305 mm) o.c. The
screws placed so as not to penetrate into the studs.
CW5: Resilient channels spaced 24” (610 mm) o.c. The resilient channels installed perpendicular to the studs using 1-5/8”
(42 mm) drywall screws.
Corridor Wall/Partition Wall Intersection
CJ1: 2x4 (38X89 mm) blocking material as required to support the RC’s of the corridor wall.
CJ2: TimberStrand®
laminated strand lumber (LSL) rimboard continuous across end of partition wall.